Bar Litre Tables

and

Boiler Pressure & Steam

Temperature Chart

 

 

Boiler Pressure & Steam Temperature Chart

 

Bar Litres (boilers up to 2 gallons)

 

To use the Bar Litre Charts first select the page applicable to the water capacity

of the boiler (the water capacity is when the boiler is completely full not the

capacity when the water is half way up the glass) then find the working

pressure of the boiler in the left hand column and move across to the right until

you come to the column equal to the capacity of the boiler. The box where the

two coincide gives you the bar litres of the boiler.

 

Example: Boiler Capacity 39 pints (22.162 litres) is on page 5. Working pressure

is 90psi (6.205bar). Read across the 90psi line to the 39 pint (22.162 litre)

column and read off the bar litres - 137.515

 

 

Walker Mickey

Insurance Brokers

Insurance for Modellers and Model Engineers

Yorkshire Bank Chambers, Fargate, Sheffield S1 2HD

Tel 0114 250 2770 Fax 0114 250 2777

www.walkennidgley.co.uk

Authorised and Regulated by the Financial Services Authority

 

 

 

 

 

Boiler Gauge Pressure Steam Temperature deg C
PSI BAR
0 0 100
5 0.35 108.52
10 0.69 115.33
15 1.03 121.02
20 1.38 126.06
25 1.72 130.51
30 2.07 134.50
35 2.41 138.14
40 2.76 141.58
45 3.10 144.66
50 3.45 147.63
55 3.79 150.41
60 4.14 153.04
65 4.48 155.53
70 4.83 157.78
75 5.17 160.02
80 5.51 162.27
85 5.86 164.31
90 6.21 166.27
95 6.55 168.15
100 6.89 169.97
105 7.24 171.72
110 7.58 173.43
115 7.92 175.15
120 8.27 176.73

 

Click here to open 1 to 9 Pints   Click here to open 8 to 16 pints